Microwave Therapy Device Emosia
Microwave therapy that reaches deep, instantly
It uniformly heats a wide area with an optimal microwave power distribution.
This ultra-short wave therapy device reduces output loss from the magnetron, which is the core, to the antenna. You can choose between a helical antenna for localized treatment and a wide antenna for treating larger areas.
Microwave therapy that reaches deep, instantly
It uniformly heats a wide area with an optimal microwave power distribution.
This ultra-short wave therapy device reduces output loss from the magnetron, which is the core, to the antenna. You can choose between a helical antenna for localized treatment and a wide antenna for treating larger areas.
Microwave therapy that reaches deep, instantly
It uniformly heats a wide area with an optimal microwave power distribution.
This ultra-short wave therapy device reduces output loss from the magnetron, which is the core, to the antenna. You can choose between a helical antenna for localized treatment and a wide antenna for treating larger areas.
Microwave therapy that reaches deep, instantly
It uniformly heats a wide area with an optimal microwave power distribution.
This ultra-short wave therapy device reduces output loss from the magnetron, which is the core, to the antenna. You can choose between a helical antenna for localized treatment and a wide antenna for treating larger areas.
Microwave therapy that reaches deep, instantly
It uniformly heats a wide area with an optimal microwave power distribution.
This ultra-short wave therapy device reduces output loss from the magnetron, which is the core, to the antenna. You can choose between a helical antenna for localized treatment and a wide antenna for treating larger areas.
Features
-
Optimal microwave power distribution heats a wide area evenly
Achieved a reduction in output loss from the magnetron, which is the core component, to the antenna.
You can choose the helical antenna for localized treatment and the wide antenna for treating larger affected areas. -
More comfortable approaches and treatment for patients
Height designed for smooth treatments on the treatment bed.
You can now choose from 2 treatment sounds and 4 completion sounds. Settings can also be changed directly on the operation panel. -
Safety features for peace of mind
・Auto over-output cutoffWhen the treatment output is gradually increased, the output is cut off if it exceeds the specified output level in the standards.
・Output zero-start functionThis function cannot output unless the volume is set to zero.
・Magnetron overheat preventionEven if components such as the magnetron cooling fan fail, the thermostat prevents overheating.
Features
-
Optimal microwave power distribution heats a wide area evenly
Achieved a reduction in output loss from the magnetron, which is the core component, to the antenna.
You can choose the helical antenna for localized treatment and the wide antenna for treating larger affected areas. -
More comfortable approaches and treatment for patients
Height designed for smooth treatments on the treatment bed.
You can now choose from 2 treatment sounds and 4 completion sounds. Settings can also be changed directly on the operation panel. -
Safety features for peace of mind
・Auto over-output cutoffWhen the treatment output is gradually increased, the output is cut off if it exceeds the specified output level in the standards.
・Output zero-start functionThis function cannot output unless the volume is set to zero.
・Magnetron overheat preventionEven if components such as the magnetron cooling fan fail, the thermostat prevents overheating.
Features
-
Optimal microwave power distribution heats a wide area evenly
Achieved a reduction in output loss from the magnetron, which is the core component, to the antenna.
You can choose the helical antenna for localized treatment and the wide antenna for treating larger affected areas. -
More comfortable approaches and treatment for patients
Height designed for smooth treatments on the treatment bed.
You can now choose from 2 treatment sounds and 4 completion sounds. Settings can also be changed directly on the operation panel. -
Safety features for peace of mind
- Auto over-output cutoffWhen the treatment output is gradually increased, the output is cut off if it exceeds the specified output level in the standards.
- Output zero-start functionThis function cannot output unless the volume is set to zero.
Magnetron overheat preventionEven if components such as the magnetron cooling fan fail, the thermostat prevents overheating.
Features
-
Optimal microwave power distribution heats a wide area evenly
Achieved a reduction in output loss from the magnetron, which is the core component, to the antenna.
You can choose the helical antenna for localized treatment and the wide antenna for treating larger affected areas.
-
More comfortable approaches and treatment for patients
Height designed for smooth treatments on the treatment bed.
You can now choose from 2 treatment sounds and 4 completion sounds. Settings can also be changed directly on the operation panel.
-
Safety features for peace of mind
- Auto over-output cutoffWhen the treatment output is gradually increased, the output is cut off if it exceeds the specified output level in the standards.
- Output zero-start functionThis function cannot output unless the volume is set to zero.
Magnetron overheat preventionEven if components such as the magnetron cooling fan fail, the thermostat prevents overheating.
Features
-
Optimal microwave power distribution heats a wide area evenly
Achieved a reduction in output loss from the magnetron, which is the core component, to the antenna.
You can choose the helical antenna for localized treatment and the wide antenna for treating larger affected areas. -
More comfortable approaches and treatment for patients
Height designed for smooth treatments on the treatment bed.
You can now choose from 2 treatment sounds and 4 completion sounds. Settings can also be changed directly on the operation panel. -
Safety features for peace of mind
- Auto over-output cutoffWhen the treatment output is gradually increased, the output is cut off if it exceeds the specified output level in the standards.
- Output zero-start functionThis function cannot output unless the volume is set to zero.
Magnetron overheat preventionEven if components such as the magnetron cooling fan fail, the thermostat prevents overheating.
Main Specifications
| Item | content |
|---|---|
| Product code | PH-W4710A |
| Brand name | Emosia 4710 |
| Generic name | Microwave therapy device |
| Supply voltage | AC 100V 50/60Hz |
| Dimensions (mm) | W450 x D300 x H690 (excluding arm) |
| JMDN code | 11245000 |
| Classification | Controlled / specially designated device (repair class 6) |
| Treatment time | 30 minutes |
| Safety device | automatic high-power cutoff circuit, zero-output start circuit, interference wave leakage prevention circuit, magnetron overheating prevention circuit |
| Electric shock protection | Class I device with Type B applied part |
| Service life | 8 years |
| Operating environment | Ambient temperature 10 to 40°C, relative humidity 30 to 75%, atmospheric pressure 700 to 1,060 hPa |
| Certification number | 229AIBZX00001000 |
| Weight | 30 kg |
| Irradiator | Helical x1 |
| Power consumption | 500VA |
| Item | content |
|---|---|
| Product code | PH-W4710C |
| Brand name | Emosia 4710 |
| Generic name | Microwave therapy device |
| Supply voltage | AC 100V 50/60Hz |
| Dimensions (mm) | W450 x D300 x H690 (excluding arm) |
| JMDN code | 11245000 |
| Classification | Controlled / specially designated device (repair class 6) |
| Treatment time | 30 minutes |
| Safety device | automatic high-power cutoff circuit, zero-output start circuit, interference wave leakage prevention circuit, magnetron overheating prevention circuit |
| Electric shock protection | Class I device with Type B applied part |
| Service life | 8 years |
| Operating environment | Ambient temperature 10 to 40°C, relative humidity 30 to 75%, atmospheric pressure 700 to 1,060 hPa |
| Certification number | 229AIBZX00001000 |
| Weight | 30 kg |
| Irradiator | Wide x1 |
| Power consumption | 500VA |
| Item | content |
|---|---|
| Product code | PH-W4720A |
| Brand name | Emosia 4720 |
| Generic name | Microwave therapy device |
| Supply voltage | AC 100V 50/60Hz |
| Dimensions (mm) | W450 x D300 x H690 (excluding arm) |
| JMDN code | 11245000 |
| Classification | Controlled / specially designated device (repair class 6) |
| Treatment time | 30 minutes |
| Safety device | automatic high-power cutoff circuit, zero-output start circuit, interference wave leakage prevention circuit, magnetron overheating prevention circuit |
| Electric shock protection | Class I device with Type B applied part |
| Service life | 8 years |
| Operating environment | Ambient temperature 10 to 40°C, relative humidity 30 to 75%, atmospheric pressure 700 to 1,060 hPa |
| Certification number | 229AIBZX00002000 |
| Weight | 43 kg |
| Irradiator | Helical x2 |
| Power consumption | 1000VA |
| Item | content |
|---|---|
| Product code | PH-W4720B |
| Brand name | Emosia 4720 |
| Generic name | Microwave therapy device |
| Supply voltage | AC 100V 50/60Hz |
| Dimensions (mm) | W450 x D300 x H690 (excluding arm) |
| JMDN code | 11245000 |
| Classification | Controlled / specially designated device (repair class 6) |
| Treatment time | 30 minutes |
| Safety device | automatic high-power cutoff circuit, zero-output start circuit, interference wave leakage prevention circuit, magnetron overheating prevention circuit |
| Electric shock protection | Class I device with Type B applied part |
| Service life | 8 years |
| Operating environment | Ambient temperature 10 to 40°C, relative humidity 30 to 75%, atmospheric pressure 700 to 1,060 hPa |
| Certification number | 229AIBZX00002000 |
| Weight | 43 kg |
| Irradiator | Helical x1 / Wide x1 |
| Power consumption | 1000VA |
| Item | content |
|---|---|
| Product code | PH-W4720C |
| Brand name | Emosia 4720 |
| Generic name | Microwave therapy device |
| Supply voltage | AC 100V 50/60Hz |
| Dimensions (mm) | W450 x D300 x H690 (excluding arm) |
| JMDN code | 11245000 |
| Classification | Controlled / specially designated device (repair class 6) |
| Treatment time | 30 minutes |
| Safety device | automatic high-power cutoff circuit, zero-output start circuit, interference wave leakage prevention circuit, magnetron overheating prevention circuit |
| Electric shock protection | Class I device with Type B applied part |
| Service life | 8 years |
| Operating environment | Ambient temperature 10 to 40°C, relative humidity 30 to 75%, atmospheric pressure 700 to 1,060 hPa |
| Certification number | 229AIBZX00002000 |
| Weight | 43 kg |
| Irradiator | Wide x2 |
| Power consumption | 1000VA |
We will send the PDF to the email address you entered.
Catalog request / contactFor the catalog of the above product and inquiries, please click the button here.